
Size it
Choose the variant and size. The pre-cured immobilizer is soft and mouldable.
Goes on soft. Hardens under UV-free light in minutes. Lets patients bathe, swim and sleep normally while the bone heals.
Trusted by hospitals and clinics on three continents






























































































The only washable, breathable cast that can be applied immediately after a closed reduction and moulded to hold it.
Soft and stretchable on the limb until you decide it is right. Shape it to the reduction, not to the material.
Rigid in minutes under UV-free light. No water bath, no 24-hour wait for full strength.
The cast sets when the clinician applies the light — after positioning, after checks, never before.
Measure the limb, choose the size. Wrap the immobilizer, zip it closed. Position the fracture, then cure with RizyCure blue light — rigid in three to five minutes, moulded to the reduction you achieved.

Choose the variant and size. The pre-cured immobilizer is soft and mouldable.

Wrap, zip and set the limb. Align the bone now — nothing changes after curing.

Three to ten minutes under the RizyCure light. The polymer hardens into a rigid, ventilated shell.
100% waterproofBathe, shower and swim.
BreathableAbout 45% open to air.
LightweightA fraction of the weight of plaster.
Zip applicationWrap, zip and lock in minutes.
ComfortableBiocompatible foam against the skin.
Latex freeNon-sensitising, non-irritating materials.
UV-free curingVisible blue light only.
RecyclableMade in a solar-powered, zero-discharge facility.
The light-cured polymer immobilizer is the core technology. Four families sit on it — from the emergency room to rehabilitation — every one washable, breathable and cured with RizyCure.

Urgent care · emergency room · post-operative
Light-cured splints and slabs for urgent and temporary immobilisation — and the preferred choice post-operatively.
5 variants
Explore →
Conservative fracture management
The original light-cured immobilizer for closed reduction and cast application — moulded to hold the reduction.
8 variants
Explore →
Second generation · remouldable
FlexiOH®'s second generation, with the capability to remould after curing — adjust as swelling settles or the plan changes.
3 variants · New
Explore →Shape-memory semi-rigid immobilisation
Semi-rigid, removable bracing for rehabilitation and post-operative immobilisation.
Coming Q4 2027 · Coming soon
Explore →







The first row is the one that matters: only a cast that can be moulded after a closed reduction can hold it.
| FlexiOH® | Plaster of Paris | Fiberglass | Thermoplastic | 3D-printed cast | |
|---|---|---|---|---|---|
| Holds a closed reduction | applied and moulded immediately after reduction | Yes | Yes | No | No |
| Application process | Cured with RizyCure light | Water bath | Water bath | Hot water bath or hot-air oven | 3D scan, model and print |
| Material sensitive to moisture | No | Yes | Yes | No | No |
| Mouldability | Easy and good | Easy and good | Poor | Easy and good | No adjustment after printing |
| Skill required | Moderate | Advanced | Advanced | Advanced | Moderate |
| Application time | 10–12 min | 30–45 min | 20–25 min | 25–30 min | 12–24 hours |
| Post-curing / setting time | 5–10 min | 10–12 hours | 15–20 min | 10–15 min | Not applicable |
| Weight | Very light | Very heavy | Light | Light | Very light |
| Rigidity | No change with heat or moisture | Strength reduces with moisture over time | Very rigid, too strong to cut | Loses rigidity at higher temperature | No change with heat or moisture |
| Washability | Absolutely washable | No | No | Partial | Absolutely washable |
| Drying after washing | Self-drying | Not applicable | Not applicable | 30 min – 1 hour, special care | Self-drying |
| Skin hygiene | Best | Poor | Poor | Better | Best |
| Dead-skin accumulation | No | Yes | Yes | Yes | No |
| Skin visible after application | Yes | No | No | No | Yes |
| Surface in contact with skin | Water non-absorbent foam | Stockinette | Stockinette | Direct skin | Direct skin |
| Skin irritation | Very little or none | High | High | Less | Very little or none |
| X-ray penetration | Partial | Very little | Partial | Partial | Yes |
Swipe the table sideways to see every column →
Source: OrthoHeal comparison of orthopaedic immobilisation generations. Clinical selection remains the treating clinician's decision.
Made in a sustainability-focused, solar-powered manufacturing facility at Vadodara, Gujarat.







A live demo, sample units, or documentation — on request.